Specification For Steam Boilers

Available Fuel: Biomass

DHL Series Biomass Fired Steam Boiler

Capacity: 20 – 75 t/h
Working Pressure: 1.25 – 5.4 Mpa
Outlet Temperature: 184 – 485 ℃
Industries: Power generation, heating, chemical, food, rubber.

Available Fuel: Bituminous coal, biomass

DHL Series Coal Fired Steam Boiler

Capacity: 20 – 75 t/h
Working Pressure: 1.25 – 5.4 Mpa
Outlet Temperature: 184 – 485 ℃
Industries: Power generation, heating, chemical, food, rubber.

Available Fuel: Bituminous coal...

DHX Coal Fired CFB Steam Boiler

Capacity: 35 – 75 t/h
Working Pressure: 1.25 – 5.3 Mpa
Outlet Temperature: 194 – 485 ℃
Industries: Chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital.

Available Fuel: Biomass particles

DZL Series Biomass Fired Steam Boiler

Capacity: 2 – 20 t/h
Working Pressure: 1 – 2.5 Mpa
Outlet Temperature: 170 – 225 ℃
Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital.

Available Fuel: Nature gas, coke oven gas...

SZS Series Gas / Oil Fired Steam Boiler

Capacity: 10 - 100 t/h
Working Pressure: 1.0 – 2.5 Mpa
Outlet Temperature: 194 – 540 °C
Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Available Fuel: Nature gas, coke oven gas...

WNS Series Gas Fired Steam Boiler

Capacity: 1 – 20 t/h
Working Pressure: 0.7 – 2 Mpa
Outlet Temperature: 194 – 540 °C
Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Volume 1, Steam Boilers - Steam, Heating Hot Water, an

2017-5-18 · PG 18-10 – STEAM, HEATING HOT WATER, AND September 1, 2016 OUTSIDE DISTRIBUTION SYSTEMS DESIGN MANUAL . Vol 1 ST EAM BOILERS 2 . 1.3 Boiler System Capacity: 1.3.1 The boiler system shall be capable of supplying the minimum demand with the smallest boiler in a normal mode of operation and with all auxiliary equipment

"boiler specification" | Water Tube Boilers supplie

SAMPLE SPECIFICATION – Bryan Steam. 2015-8-31 · Boiler shall be furnished with a UL listed forced draft flame retention gas burner. Burner shall be complete with integral motor and blower for supplying sufficient combustion air with normal vent conditions.

Boiler (power generation) - Wikiped

2019-10-13 · A boiler or steam generator is a device used to create steam by applying heat energy to water.Although the definitions are somewhat flexible, it can be said that older steam generators were commonly termed boilers and worked at low to medium pressure (7–2,000 kPa or 1–290 psi) but, at pressures above this, it is more usual to speak of a steam generator.

ENGINEERING STANDARD FOR PROCESS DESIGN O

2013-1-1 · ENGINEERING STANDARD . FOR . PROCESS DESIGN OF STEAM BOILERS . ORIGINAL EDITION . JULY 1997 . This standard specification is reviewed and updated by the relevant technical committee on Jan. 2004(1) and Oct. 2011(2). The approved modifications are included in

STEAM SYSTEMS - cleaverbrooks.c

2018-8-5 · steam boilers with a MAWP of 15 psig or lower. B31.1 Power Piping Code provides rules for most of the piping systems involved in a typical steam plant, but has special significance relative to Section I in that it contains Certification and Stamping requirements for boiler external piping (BEP). BEP is defined as piping

ELECTRIC STEAM BOILERS - acmeprod.c

2017-7-27 · TYPICAL SPECIFICATION ELECTRIC STEAM BOILERS Receipt, inspection and storage of equipment at the job site in a clean dry location suitable for electrical equipment. Installation of the unit including all external wiring and piping. Power supply wiring from main service panel through circuit breaker or disconnect switch (if required, and if mounted

boilers specification data she

universal steam boiler technical specification - Steam . Burner Specification & Data sheet Water & steam boilers 80 Burner model Burner used on boiler models: Motor size H.P. Motor electrical characteristics Gas train size (inches) Length (from mounting flange to label area on burner front) Overall width ( not including gas . GET A QUOTE. Get a

CB Specifications - Ste

2018-8-5 · Model CB 15-100 HP Model CB Steam Boiler (15-100 hp, Steam 15-350 psig) The following sample specification is provided by Cleaver-Brooks to assist you in meeting your customer's specific needs and application. A separate specification for steam boilers and hot water boilers is provided.

Thermax - Packaged-Boile

Steam Boilers Up to 40 TPH capacity. Thermal Oil Heaters and Vapourisers Up to 25 Gcal/hcapacity. Hot Water Generators Up to 17 Gcal/h Capacity. Hot Air Generators Up to 3 Gcal/h capacity . DOWNLOAD BROCHURE. DOWNLOAD BROCHURE. Shellmax is a packaged, three-pass smoke tube, with fully wet back boiler. Shellmax comes in two series – SMDL for

Chapter 9 Boilers - NAVY B

2016-7-4 · water or steam, to produce a source for either heat or power. A central heating plant may have one or more boilers that use gas, oil, or coal as fuel. The steam generated is used to heat buildings, provide hot water, and provide steam for cleaning, sterilizing, cooking, and laundering operations. Small package boilers also provide steam and hot

Bryan Boilers BE-210-W4T7 Specification - ManualsL

Page 2 Applications include hot water heating, steam heating, process heating, and supplemental heat for heat pump type equipment. All Bryan Boilers are built in accordance with the requirements of the ASME boiler and pressure vessel code and are UL listed. Water boilers are 150 psig MAWP and steam boilers either 15 psig or 150 psig.